BXXQF - ELDORADO CT-2500
- MSDS: BXXQF
- Manufacturer: ELDORADO CHEMICAL COMPANY INC
- Product Name: ELDORADO CT-2500
- National Stock Number: 6850-00D004107
Product Identification
Product ID:ELDORADO CT-2500
MSDS Date:05/19/1997
FSC:6850
NIIN:00D004107
MSDS Number: BXXQF
Responsible Party
SAN ANTONIO, TX 78265
US
Emergency Phone: 800-255-3924 (CHEMTEL)
Info Phone: 512-653-9323
Preparer: BOB E. FLYNT
Cage: 55208
Contractor
Telephone: 800-531-1088/ 210-653-2060
Cage: 55208
Ingredients
METHYLENE CHLORIDE (SARA 313) (CERCLA)
CAS: 75-09-2
RTECS: PA8050000
Fraction By Weight: 60%
OSHA PEL 25 PPM, Z-2
ACGIH TLV: 50 PPM, A2; 9596
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
SODIUM CHROMATE (SARA 313) (CERCLA)
CAS: 7775-11-3
RTECS: GB2955000
Fraction By Weight: 0.02%
OSHA PEL C 0.1 MG (CRO3)/M3
ACGIH TLV: 0.05 MG(CR)/M3;A1;96
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
PHENOL (SARA 302/313) (CERCLA)
CAS: 108-95-2
RTECS: SJ3327000
Fraction By Weight: 15%
OSHA PEL S, 5 PPM
ACGIH TLV: S, 5 PPM; 9596
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION INDUCES NARCOSIS,
DIZZINESS, NAUSEA. CONTACT IS HIGHLY CORROSIVE TO SKIN & EYES. NO
DATA GIVEN ON IBGESTION. CHRONIC: PROLONGED OR REPEATED EXPOSURE
MAY CAUSE CANCER.
Explanation of Carcinogenicity:SUSPECTED CARCINOGEN BY ANIMAL STUDIES
(CHROMATE).
Effects of Overexposure:INHALATION-INDUCES NARCOSIS, DIZZINESS, NAUSEA.
SKIN-CORROSIVE TO SKIN, WILL CAUSE SCARRING WHICH WILL DISAPPEAR IN
1-2 YEARS. PAINFUL ON CONTACT, NO CHRONIC EXPOSURE EXPECTED.
EYE-CORROSIVE TO EYES O N CONTACT, SHORT EXPOSURE. WILL CAUSE HAZY
VISION WHICH RETURNS TO NORMAL.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES-FLUSH WITH WATER FOR 15 MINUTES, SEEK MEDICAL ATTENTION.
SKIN-FLUSH WITH WATER FOR 10 MINUTES, WASH WITH SOAP AND WATER.
INHALATION-REMOVE TO FRESH AIR, IF UNCONSCIOUS, GIVE OXYGEN AND
SEEK MEDIC AL ATTENTION. INGESTION-DRINK PLENTY OFWATER; CONSULT
PHYSICIAN.
Fire Fighting
Flash Point:NONE
Extinguishing Media:N/A. DLA-HMIS: MEDIA APPROPRIATE FOR SURROUNDING
FIRE.
Fire Fighting Procedures:SELF-CONTAINED BREATHING APPARATUS REQUIRED.
Unusual Fire/Explosion Hazard:CONTACT WITH FLAME MAY PRODUCE TOXIC
CHLORIDE FUMES AND/OR PHOSGENE GAS.
Accidental Release
Spill Release Procedures:CONTAIN WITH ABSORBENT; SWEEP UP RESIDUE WITH
SAWDUST OR SWEEPING COMPOUND.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:SELF-CONTAINED BREATHING APPARATUS IF LIMITS
EXCEEDED.
Ventilation:100 FT/MIN.
Protective Gloves:POLYETHYLENE GLOVES.
Eye Protection:FACE SHIELD OR GOGGLES.
Other Protective Equipment:RUBBER CLOTHING, RUBBER APRONS AND BOOTS.
Work Hygienic Practices:AVOID ALL SKIN CONTACT.
Supplemental Safety and Health
NONE
Chemical Properties
HCC:T3
Boiling Pt:B.P. Text:115F,46C
Vapor Pres:200
Vapor Density:2
Spec Gravity:1.2
pH:12
Evaporation Rate & Reference:1
Solubility in Water:INSOLUBLE
Appearance and Odor:DIPHASE, THIN, PUNGENT LIQUID.
Percent Volatiles by Volume:90
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ALKALIS, STRONG ACIDS, OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:HEAT WILL PRODUCE DICHLOROMETHANE
FUMES.
Disposal
Waste Disposal Methods:AS IS: PRODUCT HAS A D007 HAZARDOUS WASTE CODE,
AND CONTAINS U052, U080, AND U188. CONSULT FEDERAL, STATE AND LOCAL
REGULATORY AGENCIES FOR PROPER DISPOSAL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.